ControllerLast modified on 2023-06-23 11:21 |
Submit Comment |
| ID | Type | Name | Description | Links |
|---|---|---|---|---|
| Controller-MIB-1 | comment | comment |
Header
|
|
| Controller-MIB-2 | mib | DEFINITIONS |
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY, Unsigned32 |
|
| Controller-MIB-3 | module-identity | fdControllerMIB |
The MIB that defines basic information that is generic to most field device controllers. Copyright (C) International Organization for Standardization (ISO). This MIB module is part of ISO 26048-1; see ISO 26048-1 for full legal notices. |
|
| Controller-MIB-4 | comment | comment |
Object Definitions
|
|
| Controller-MIB-5 | object-type | fdConfigurationID |
1 Configuration identifierA relatively unique identifier that shall change when and only when there is a change to one or more of the configuration parameters stored within the device. The value shall be determined by a formula that always produces the same value for a given configuration. For example, if a parameter changes, the value of this object shall change and if that parameter is changed back to its original value, the vaklue of this object will return to its previous value. \ For example, the identifier may reflect a checksum. |
Satisfies:
26048_1-298 Monitor the field device
configuration i…
|
| Controller-MIB-6 | object-type | fdConfigurationChangedBy |
2 Configuration changed byThe securityName used to make the last change to a configuration parameter within the field device. The field device specification shall identify which object types are considered configuration parameters. |
Satisfies:
26048_1-298 Monitor the field device
configuration i…
|
| Controller-MIB-7 | object-type | fdWatchdogFailures |
3 Watchdog failuresIndicates the number of times the watchdog timer elapsed (i.e., reported a suspected error condition in the device) since the last initialization of the SNMP engine. |
Satisfies:
26048_1-307 Monitor watchdog failure count
|
| Controller-MIB-8 | object-type | fdControllerStatus |
4 Controller statusA bitmap that indicates if there are any errors currently detected in the field device. other - an error not defined by the other values of this object; the error may be related to objects defined by other standards, other parts of the ISO 20684 series, or proprietary conditions. prom - an error with the programable read-only memory ram - an error with the random access memory program - an error detected in the program or processor display - an error associated with the display on the controller gpio - a bit is set on one or more of the fdGPIOTypeStatus objects |
Satisfies:
26048_1-299 Monitor controller operation
|
| Controller-MIB-9 | object-type | fdControllerReset |
5 Controller resetA mechanism allowing the manager to reset/reboot the field device. SETting this value to 'true' shall cause the field device to reset (but will not modify values stored in changeable memory). Once the controller resets, the value of this object shall return to 'false'. SETting this value to 'false' shall result in a 'wrongValue' error. |
Satisfies:
26048_1-308 Reset the controller
|
| Controller-MIB-10 | object-type | fdTotalChangeableMemory |
6 Total changeable memoryThe total amount of 'non-volatile' memory supported by the device whose values are able to survive a power loss. |
Satisfies:
26048_1-287 Discover basic capabilities of the contr…
|
| Controller-MIB-11 | object-type | fdFreeChangeableMemory |
7 Free changeable memoryThe amount of free 'non-volatile' memory available whose values is able to survive a power loss. |
Satisfies:
26048_1-287 Discover basic capabilities of the contr…
|
| Controller-MIB-12 | object-type | fdTotalVolatileMemory |
8 Total volatile memoryThe total amount of memory supported by the device whose values will not survive a power loss. |
Satisfies:
26048_1-287 Discover basic capabilities of the contr…
|
| Controller-MIB-13 | object-type | fdFreeVolatileMemory |
9 Free volatile memoryThe amount of free memory available whose values will not survive a power loss. |
Satisfies:
26048_1-287 Discover basic capabilities of the contr…
|
| Controller-MIB-14 | object-type | fdDefaultLanguage |
10 Default languageThe two-letter ISO 639-1 code in lowercase letters that identifies the language that the controller should use when populating textual fields based on internal controller logic (e.g., when producing a textual error message to the user). Implementations should restrict the range of values supported for this object to those codes that represent languages for which the controller can provide messages. This setting does not restrict users from entering values in other languages in writable objects. |
Satisfies:
26048_1-309 Configure the default language
26048_1-310 Determine the current default language
|
| Controller-MIB-15 | comment | comment |
Conformance Information
|
|
| Controller-MIB-16 | object-identity | fdControllerConformance |
A node defining conformance information related to the field device controller objects. |
|
| Controller-MIB-17 | object-identity | fdControllerCompliances |
A node for compliance statements for the controller objects. |
|
| Controller-MIB-18 | object-identity | fdControllerGroups |
A node for group definitions related to controller objects. |
|
| Controller-MIB-19 | module-compliance | fdControllerComplianceV1 |
The original compliance statement for controller objects. |
|
| Controller-MIB-20 | object-group | fdControllerGroupV1 |
The objects required to claim conformance to the first version of the controller group. |
|
| Controller-MIB-21 | end | end |